Full Wave Rectifier
INSTRUCTION
- Connect the components as mentioned below:
L1-L7, L4-L7, L12-L5, L12-L11, L8-L9, L6-L10, L3-L11, L10-L8.(For eg. click on 1 and then drag to 3 and so on.)
- Click on 'Check Connection' button to check the connections.
- If connected wrong click on 'Delete all connection' button to erase all the connections.
- Set the resistor \(R_L\).
- Click on 'ON' button to start the experiment.
- Click on 'Sine Wave' button to generate input waveform
- Click on 'Oscilloscope' button to get the rectified output.
- Vary the Amplitude, Frequency, volt/div using the controllers.
- Click on "Dual" button to observe both the waveform.
- Channel 1 shows the input sine waveform, Channel 2 shows the output rectified waveform.
- Calculate the Ripple Factor.Theoretical Ripple Factor= 0.483.