Zener characteristics
INSTRUCTION
- Select the diode
- Set the rheostat Rh=1 Ω
- By adjusting the rheostat, voltmeter reading is increased from 0 and in each time note the corresponding reading in milliammeter.
- Take the readings and note Voltmeter reading across Zener diode and Ammeter reading.
- Plot the V-I graph and observe the change.
Serial No. |
Zener Voltage(Volt) |
Current(mAmp) |